Datasheet
Section 11 16-Bit Free-Running Timer (FRT)
Rev. 3.00 Mar 21, 2006 page 267 of 788
REJ09B0300-0300
Bit Bit Name Initial Value R/W Description
3 OCFA 0 R/(W)
*
Output Compare Flag A
This status flag indicates that the FRC value matches
the OCRA value. Only 0 can be written to this bit to
clear the flag.
[Setting condition]
When FRC = OCRA
[Clearing condition]
Read OCFA when OCFA = 1, then write 0 to OCFA
2 OCFB 0 R/(W)
*
Output Compare Flag B
This status flag indicates that the FRC value matches
the OCRB value. Only 0 can be written to this bit to
clear the flag.
[Setting condition]
When FRC = OCRB
[Clearing condition]
Read OCFB when OCFB = 1, then write 0 to OCFB
1OVF 0 R/(W)
*
Timer Overflow
This status flag indicates that the FRC has overflowed.
Only 0 can be written to this bit to clear the flag.
[Setting condition]
When FRC overflows (changes from H'FFFF to H'0000)
[Clearing condition]
Read OVF when OVF = 1, then write 0 to OVF
0 CCLRA 0 R/W Counter Clear A
This bit selects whether the FRC is to be cleared at
compare-match A (when the FRC and OCRA values
match).
0: FRC clearing is disabled
1: FRC is cleared at compare-match A
Note: * Only 0 can be written to clear the flag.