Datasheet

Section 26 Electrical Characteristics
Rev. 4.00 Sep 27, 2006 page 789 of 1130
REJ09B0327-0400
Table 26.8 Bus Timing (2) (Advanced mode)
Condition A: V
CC
= 5.0 V ±10%, V
CC
B = 5.0 V ±10%, V
SS
= 0 V, φ = 2 MHz to maximum
operating frequency, T
a
= –20 to +75°C (regular specifications),
T
a
= –40 to +85°C (wide-range specifications)
Condition B: V
CC
= 4.0 V to 5.5 V, V
CC
B = 4.0 V to 5.5 V, V
SS
= 0 V, φ = 2 MHz to maximum
operating frequency, T
a
= –20 to +75°C (regular specifications),
T
a
= –40 to +85°C (wide-range specifications)
Condition C: V
CC
= 3.0 V to 5.5 V, V
CC
B = 3.0 V to 5.5 V, V
SS
= 0 V, φ = 2 MHz to maximum
operating frequency, T
a
= –20 to +75°C
Condition A Condition B Condition C
20 MHz 16 MHz 10 MHz
Item Symbol Min Max Min Max Min Max Unit
Test
Conditions
Address
delay time
t
AD
30 45 60 ns
Address
setup time
t
AS
0.5 ×
t
cyc
25
0.5 ×
t
cyc
35
0.5 ×
t
cyc
50
ns
Figure 26.10
to
figure 26.14
Address
hold time
t
AH
0.5 ×
t
cyc
10
0.5 ×
t
cyc
15
0.5 ×
t
cyc
20
ns
CS delay
time (IOS)
t
CSD
30 45 60 ns
AS delay
time
t
ASD
30 45 60 ns
RD delay
time 1
t
RSD1
30 45 60 ns
RD delay
time 2
t
RSD2
30 45 60 ns
Read data
setup time
t
RDS
15 20 35 ns
Read data
hold time
t
RDH
0 0 0 ns
Read data
access
time 1
t
ACC1
1.0 ×
t
cyc
40
1.0 ×
t
cyc
55
1.0 ×
t
cyc
80
ns
Read data
access
time 2
t
ACC2
1.5 ×
t
cyc
25
1.5 ×
t
cyc
35
1.5 ×