Datasheet

Section 2 CPU
Rev. 4.00 Sep 27, 2006 page 52 of 1130
REJ09B0327-0400
2.6 Instruction Set
2.6.1 Overview
The H8S/2000 CPU has 65 types of instructions. The instructions are classified by function in
table 2.1.
Table 2.1 Instruction Classification
Function Instructions Size Types
Data transfer MOV BWL 5
POP
*
1
, PUSH
*
1
WL
LDM
*
5
, STM
*
5
L
MOVFPE
*
3
, MOVTPE
*
3
B
ADD, SUB, CMP, NEG BWL 19Arithmetic
operations
ADDX, SUBX, DAA, DAS B
INC, DEC BWL
ADDS, SUBS L
MULXU, DIVXU, MULXS, DIVXS BW
EXTU, EXTS WL
TAS
*
4
B
Logic operations AND, OR, XOR, NOT BWL 4
Shift SHAL, SHAR, SHLL, SHLR, ROTL, ROTR, ROTXL, ROTXR BWL 8
Bit-manipulation BSET, BCLR, BNOT, BTST, BLD, BILD, BST, BIST, BAND,
BIAND, BOR, BIOR, BXOR, BIXOR
B14
Branch Bcc
*
2
, JMP, BSR, JSR, RTS 5
System control TRAPA, RTE, SLEEP, LDC, STC, ANDC, ORC, XORC, NOP 9
Block data transfer EEPMOV 1
Total: 65 types
Legend: B: Byte
W: Word
L: Longword
Notes: 1. POP.W Rn and PUSH.W Rn are identical to MOV.W @SP+, Rn and MOV.W Rn,
@-SP.
POP.L ERn and PUSH.L ERn are identical to MOV.L @SP+, ERn and MOV.L ERn,
@-SP.
2. Bcc is the general name for conditional branch instructions.
3. Cannot be used in this LSI.
4. Only register ER0, ER1, ER4, or ER5 should be used when using the TAS instruction.
5. Only registers ER0 to ER6 should be used when using the STM/LDM instruction.