Section 26 Electrical Characteristics
Rev. 3.00 Sep. 28, 2009 Page 884 of 910
REJ09B0350-0300
26.3.2 Control Signal Timing
Table 26.6 shows the control signal timing. Only external interrupts NMI, IRQ0 to IRQ15, KIN0
to KIN15, WUE8 to WUE15, and KBCA to KBCD can be operated based on the subclock (φ =
32.768 kHz).
Table 26.6 Control Signal Timing
Conditions: V
CC
= 3.0 V to 3.6 V, V
SS
= 0 V, φ = 32.768 kHz, 8 MHz to maximum operating
frequency
Item Symbol Min. Max. Unit
Test
Conditions
RES setup time t
RESS
200 ns
RES pulse width t
RESW
20 t
cyc
Figure 26.7
NMI setup time t
NMIS
150
NMI hold time t
NMIH
10
NMI pulse width
(exiting software standby mode)
t
NMIW
200
IRQ setup time
(IRQ15 to IRQ0, KIN15 to KIN0,
WUE15 to WUE8)
t
IRQS
150
IRQ hold time
(IRQ15 to IRQ0, KIN15 to KIN0,
WUE15 to WUE8)
t
IRQH
10
ns Figure 26.8
IRQ pulse width
(IRQ15 to IRQ0, KIN15 to KIN0,
WUE15 to WUE8)
(exiting software standby mode)
t
IRQW
200
t
RESW
t
RESS
φ
t
RESS
RES
Figure 26.7 Reset Input Timing