Datasheet
Section 15 Serial Communication Interface (SCI)
Rev. 3.00 Sep. 28, 2009 Page 464 of 910
REJ09B0350-0300
(2) Reception
Before making the transition to module stop, software standby or watch mode, stop reception (RE
= 0). RSR, RDR, and SSR are reset. If transition is made during data reception, the data being
received will be invalid.
To receive data in the same reception mode after mode cancellation, set RE to 1, and then start
reception. To receive data in a different reception mode, initialize the SCI first.
Figure 15.36 shows a sample flowchart for mode transition during reception.
Start reception
Reception
[1]
No
No
Yes
Yes
Read receive data in RDR
Read RDRF flag in SSR
Make transition to
software standby mode etc.
Cancel software standby mode etc.
RE = 0
Initialization RE = 1
[2]
Change operating mode?
RDRF = 1
[1] Data being received will be invalid.
[2] Module stop mode and watch mode are
included.
Figure 15.36 Sample Flowchart for Mode Transition during Reception