Datasheet

Section 10 16-Bit Timer Pulse Unit (TPU)
Rev. 3.00 Sep. 28, 2009 Page 272 of 910
REJ09B0350-0300
(b) Example of input capture operation
Figure 10.13 shows an example of input capture operation. In this example both rising and falling
edges have been selected as the TIOCA pin input capture input edge, falling edge has been
selected as the TIOCB pin input capture input edge, and counter clearing by TGRB input capture
has been designated for TCNT.
TCNT value
H'0180
H'0000
TIOCA
TGRA
H'0010
H'0005
Counter cleared by TIOCB
input (falling edge)
H'0160
H'0005 H'0160 H'0010
TGRB
H'0180
TIOCB
Time
Figure 10.13 Example of Input Capture Operation