Datasheet
Section 15 Serial Communication Interface (SCI, IrDA)
Rev. 3.00 Mar 17, 2006 page 676 of 926
REJ09B0283-0300
Bit Bit Name Initial Value R/W Description
5 ORER 0 R/(W)
*
Overrun Error
[Setting condition]
When the next serial reception is completed while
RDRF = 1
[Clearing condition]
When 0 is written to ORER after reading ORER =
1
4ERS 0 R/(W)
*
Error Signal Status
[Setting condition]
When the low level of the error signal is sampled
[Clearing condition]
When 0 is written to ERS after reading ERS = 1
3 PER 0 R/(W)
*
Parity Error
[Setting condition]
When a parity error is detected during reception
[Clearing condition]
When 0 is written to PER after reading PER = 1