Section 6 Bus Controller (BSC)
Rev. 3.00 Mar 17, 2006 page 179 of 926
REJ09B0283-0300
If a row address hold time or read access time is necessary, making a setting in bits RCD1 and
RCD0 in DRACCR allows from one to three T
rw
states, in which row address output is maintained,
to be inserted between the T
r
cycle, in which the RAS signal goes low, and the T
c1
cycle, in which
the column address is output. Use the setting that gives the optimum row address signal hold time
relative to the falling edge of the RAS signal according to the DRAM connected and the operating
frequency of this LSI. Figure 6.24 shows an example of the timing when one T
rw
state is set.
T
p
φ
RASn (CSn)
Read
Write
UCAS, LCAS
WE
(HWR)
OE (RD)
Data bus
WE (HWR)
OE (RD)
Data bus
Address bus
T
r
T
rw
T
c1
T
c2
Row address Column address
High
High
Note: n = 2 to 5
Figure 6.24 Example of Timing with One Row Address Output Maintenance State