Datasheet
Rev.6.00 Oct.28.2004 page 760 of 1016
REJ09B0138-0600H
(2) Control Signal Timing
Table 22-37 lists the control signal timing.
Table 22-37 Control Signal Timing
Condition B: V
CC
 = 5.0 V ± 10%, AV
CC
 = 5.0 V ± 10%, V
ref
 = 4.5 V to AV
CC
,
V
SS
 = AV
SS
 = 0 V, ø = 2 to 20 MHz, T
a
 = –20 to +75°C (regular specifications),
T
a
 = –40 to +85°C (wide-range specifications)
Condition C: V
CC
 = 3.0 to 5.5 V, AV
CC
 = 3.0 to 5.5 V, V
ref
 = 3.0 V to AV
CC
,
V
SS
 = AV
SS
 = 0 V, ø = 2 to 13 MHz, T
a
 = –20 to +75°C (regular specifications),
T
a
 = –40 to +85°C (wide-range specifications)
Condition B Condition C
Item Symbol Min Max Min Max Unit Test Conditions
RES setup time t
 RESS
200 — 200 — ns Figure 22-70
RES pulse width t
 RESW
20 — 20 — t
 cyc
NMI setup time t
 NMIS
150 — 250 — ns Figure 22-71
NMI hold time t
 NMIH
10 — 10 —
NMI pulse width (exiting
software standby mode)
t
 NMIW
200 — 200 — ns
IRQ setup time t
 IRQS
150 — 250 — ns
IRQ hold time t
 IRQH
10 — 10 — ns
IRQ pulse width (exiting
software standby mode)
t
 IRQW
200 — 200 — ns