Datasheet
Rev.6.00 Oct.28.2004 page 372 of 1016
REJ09B0138-0600H
10.4.2 Basic Functions
Counter Operation: When one of bits CST0 to CST5 is set to 1 in TSTR, the TCNT counter for the corresponding
channel starts counting. TCNT can operate as a free-running counter, periodic counter, and so on.
•  Example of count operation setting procedure
Figure 10-6 shows an example of the count operation setting procedure.
Select counter clock
Operation selection
Select counter clearing source
Periodic counter
Set period
Start count operation
<Periodic counter>
[1]
[2]
[4]
[3]
[5]
Free-running counter
Start count operation
<Free-running counter>
[5]
[1]
[2]
[3]
[4]
[5]
Select output compare register
Select the counter 
clock with bits 
TPSC2 to TPSC0 in 
TCR. At the same 
time, select the 
input clock edge 
with bits CKEG1 
and CKEG0 in TCR.
For periodic counter 
operation, select the 
TGR to be used as 
the TCNT clearing 
source with bits 
CCLR2 to CCLR0 in 
TCR.
Designate the TGR 
selected in [2] as an 
output compare 
register by means of 
TIOR.
Set the periodic 
counter cycle in the 
TGR selected in [2].
Set the CST bit in 
TSTR to 1 to start 
the counter 
operation.
Figure 10-6 Example of Counter Operation Setting Procedure