Section 11 Programmable Pulse Generator (PPG)
Rev.6.00 Sep. 27, 2007 Page 547 of 1268
REJ09B0220-0600
11.3.3 Normal Pulse Output
Sample Setup Procedure for Normal Pulse Output: Figure 11.4 shows a sample procedure for
setting up normal pulse output.
Select TGR functions
[1]
Set TGRA value
Set counting operation
Select interrupt request
Set initial output data
Enable pulse output
Select output trigger
Set next pulse
output data
Start count
Set next pulse
output data
Normal PPG output
No
Yes
TPU setup
Port and
PPG setup
TPU setup
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
Compare match?
[1] Set TIOR to make TGRA an output
compare register (with output
disabled).
[2] Set the PPG output trigger period.
[3] Select the counter clock source
with bits TPSC2 to TPSC0 in TCR.
Select the counter clear source
with bits CCLR1 and CCLR0.
[4] Enable the TGIA interrupt in TIER.
The DTC or DMAC* can also be
set up to transfer data to NDR.
[5] Set the initial output values in
PODR.
[6]
Set the DDR and NDER bits for the
pins to be used for pulse output to 1.
[7] Select the TPU compare match
event to be used as the output
trigger in PCR.
[8] Set the next pulse output values in
NDR.
[9] Set the CST bit in TSTR to 1 to
start the TCNT counter.
[10]
At each TGIA interrupt, set the next
output values in NDR.
Note:* The DMAC is not supported in
the H8S/2321.
Figure 11.4 Setup Procedure for Normal Pulse Output (Example)