Datasheet
Section 11 Programmable Pulse Generator (PPG)
Rev.6.00 Sep. 27, 2007 Page 536 of 1268
REJ09B0220-0600
NDERL Bits 7 to 0—Next Data Enable 7 to 0 (NDER7 to NDER0): These bits enable or
disable pulse output on a bit-by-bit basis.
Bits 7 to 0
NDER7 to NDER0
Description
0 Pulse outputs PO7 to PO0 are disabled (NDR7 to NDR0 are not
transferred to POD7 to POD0) (Initial value)
1 Pulse outputs PO7 to PO0 are enabled (NDR7 to NDR0 are transferred to
POD7 to POD0)
11.2.2 Output Data Registers H and L (PODRH, PODRL)
PODRH
Bit : 7 6 5 4 3 2 1 0
POD15 POD14 POD13 POD12 POD11 POD10 POD9 POD8
Initial value : 0 0 0 0 0 0 0 0
R/W : R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
PODRL
Bit : 7 6 5 4 3 2 1 0
POD7 POD6 POD5 POD4 POD3 POD2 POD1 POD0
Initial value : 0 0 0 0 0 0 0 0
R/W : R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
R/(W)
*
Note: * A bit that has been set for pulse output by NDER is read-only.
PODRH and PODRL are 8-bit readable/writable registers that store output data for use in pulse
output.