Section 10 16-Bit Timer Pulse Unit (TPU)
Rev.6.00 Sep. 27, 2007 Page 479 of 1268
REJ09B0220-0600
10.2.9 Timer Synchro Register (TSYR)
Bit : 7 6 5 4 3 2 1 0
— — SYNC5 SYNC4 SYNC3 SYNC2 SYNC1 SYNC0
Initial value : 0 0 0 0 0 0 0 0
R/W : — — R/W R/W R/W R/W R/W R/W
TSYR is an 8-bit readable/writable register that selects independent operation or synchronous
operation for the channel 0 to 4 TCNT counters. A channel performs synchronous operation when
the corresponding bit in TSYR is set to 1.
TSYR is initialized to H'00 by a reset and in hardware standby mode.
Bits 7 and 6—Reserved: Must always be written with 0.
Bits 5 to 0—Timer Synchro 5 to 0 (SYNC5 to SYNC0): These bits select whether operation is
independent of or synchronized with other channels.
When synchronous operation is selected, synchronous presetting of multiple channels
*
1
, and
synchronous clearing through counter clearing on another channel
*
2
are possible.
Bit n
SYNCn
Description
0 TCNTn operates independently (TCNT presetting/clearing is unrelated to
other channels) (Initial value)
1 TCNTn performs synchronous operation
TCNT synchronous presetting
*
1
/synchronous clearing
*
2
is possible
n = 5 to 0
Notes: 1. To set synchronous operation, the SYNC bits for at least two channels must be set to 1.
2. To set synchronous clearing, in addition to the SYNC bit , the TCNT clearing source
must also be set by means of bits CCLR2 to CCLR0 in TCR.