Datasheet

Section 6 Bus Controller
Rev.6.00 Sep. 27, 2007 Page 172 of 1268
REJ09B0220-0600
6.4.3 Valid Strobes
Table 6.4 shows the data buses used and valid strobes for the access spaces.
In a read, the RD signal is valid without discrimination between the upper and lower halves of the
data bus.
In a write, the HWR signal is valid for the upper half of the data bus, and the LWR signal for the
lower half.
Table 6.4 Data Buses Used and Valid Strobes
Area
Access
Size
Read/
Write
Address
Valid
Strobe
Upper Data Bus
(D
15
to D
8
)
Lower Data Bus
(D
7
to D
0
)
Byte Read RD Valid Invalid
8-bit access
space
Write HWR Hi-Z
Byte Read Even RD Valid Invalid 16-bit access
space
Odd Invalid Valid
Write Even HWR Valid Hi-Z
Odd LWR Hi-Z Valid
Word Read RD Valid Valid
Write HWR, LWR Valid Valid
Notes: Hi-Z: High impedance
Invalid: Input state; input value is ignored.