RL78/G1A CHAPTER 13 SERIAL INTERFACE IICA
(2) When communication reservation function is disabled (bit 0 (IICRSV) of IICA flag register 0 (IICF0) = 1)
When bit 1 (STT0) of IICA control register 00 (IICCTL00) is set to 1 when the bus is not used in a communication
during bus communication, this request is rejected and a start condition is not generated. The following two
statuses are included in the status where bus is not used.
When arbitration results in neither master nor slave operation
When an extension code is received and slave operation is disabled (ACK is not returned and the bus was
released by setting bit 6 (LREL0) of the IICCTL00 register to 1 and saving communication)
To confirm whether the start condition was generated or request was rejected, check STCF (bit 7 of the IICF0
register). It takes up to 5 clocks of f
MCK until the STCF bit is set to 1 after setting STT0 = 1. Therefore, secure the
time by software.