Users Manual

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 1176 of 1852
Nov 30, 2020
RX23W Group 35. I
2
C-bus Interface (RIICa)
Figure 35.28 Set/Clear Timing of the AASy and DID Flags during Reception of Device-ID Address
[Device-ID reception]
SCL0
SDA0
BBSY
AASy
DID
TRS
TDRE
RDRF
1234567891 89 123456789
S
1111100W#A
Device-ID address matches (1111 100b + W#)
Address A
Slave address matches
Received data (7-bit address/lower bits of 10-bit address)
Read ICDRR register
(Dummy read (7-bit address/lower bits of 10-bit address))
Sr
1111100RA
Device-ID address matches (1111 100b + R)
[When the address following a restart condition is not a device-ID address]
SCL0
SDA0
BBSY
AASy
DID
RDRF
1234567891 89 123456789
S
1111100W#A
Device-ID address matches (1111 100b + W#)
A
Slave address matches
Address
Received data (7-bit address/lower bits of 10-bit address)
Read ICDRR register
(Dummy read (7-bit address/lower bits of 10-bit address))
Sr
A7-bit slave address (for another slave) R/W#
Device-ID address does not match
Slave address does not match
[When the address before the device-ID address + R had not matched the slave address]
SCL0
SDA0
BBSY
AASy
DID
TDRE
1234567891 89 123456789
S
1111100RA#
Device-ID address matches (1111 100b + R)
Address A#
Sr
A#
The previous value is held
RDRF
1111100R
Device-ID address matches (1111 100b + R)
The following address is not compared