16.3.3 Bus Error Status Register 1 (BERSR1)
MST[2:0] Bits (Bus Master Code)
These bits indicate the bus master that accessed a bus when a bus error occurred.
16.3.4 Bus Error Status Register 2 (BERSR2)
Address(es): 0008 1308h
b7 b6 b5 b4 b3 b2 b1 b0
MST[2:0] TO IA
Value after reset:
00000000
Bit Symbol Bit Name Description R/W
b0 IA Illegal Address Access 0: Illegal address access not made
1: Illegal address access made
R
b1 TO Timeout 0: Timeout not generated
1: Timeout generated
R
b3, b2 Reserved These bits are read as 0. Writing to these bits has no effect. R
b6 to b4 MST[2:0] Bus Master Code
b6 b4
0 0 0: CPU
0 0 1: Reserved
0 1 0: Reserved
0 1 1: DTC/DMAC
1 0 0: Reserved
1 0 1: Reserved
1 1 0: Reserved
1 1 1: Reserved
R
b7 Reserved This bit is read as 0. Writing to this bit has no effect. R
Address(es): 0008 130Ah
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
ADDR[12:0] ———
Value after reset:
0000000000000000
Bit Symbol Bit Name Description R/W
b2 to b0 Reserved These bits are read as 0. Writing to these bits has no effect. R
b15 to b3 ADDR[12:0] Bus Error
Occurrence Address
The upper 13 bits of an address that was accessed when a bus error
occurred (in units of 512 Kbytes).