Product Info

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 629 of 1852
Nov 30, 2020
RX23W Group 23. Multi-Function Timer Pulse Unit 2 (MTU2a)
(11) Operation When Error Occurs in PWM Mode 1 and Operation is Restarted in Complementary
PWM Mode
Figure 23.126 shows a case in which an error occurs in PWM mode 1 and operation is restarted in complementary
PWM mode after re-setting.
Figure 23.126 Error Occurrence in PWM Mode 1, Recovery in Complementary PWM Mode
(1) to (10) are the same as in Figure 23.122.
(11) Set normal mode to initialize the normal mode waveform generation block.
(12) Initialize the PWM mode 1 waveform generation block with the TIOR register.
(13) Disable operation of the PWM mode 1 waveform generation block with the TIOR register.
(14) Disable output in MTU3 and MTU4 with the TOER register.
(15) Select the complementary PWM mode output level and enable or disable cyclic output with the TOCR register.
(16) Set complementary PWM mode.
(17) Enable output in MTU3 and MTU4 with the TOER register.
(18) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(19) Restart operation by setting the TSTR register.
(1)
Reset
MTU module output
(2)
TMDR
(PWM1)
(3)
TOER
(1)
(4)
TIOR
(1 init
0 out)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(normal)
(12)
TIOR
(0 init
0 out)
(13)
TIOR
(disabled)
(14)
TOER
(0)
(15)
TOCR
(16)
TMDR
(CPWM)
(17)
TOER
(1)
(19)
TSTR
(1)
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(5)
MPC
(MTU)
(18)
MPC
(MTU)
Hi-Z
Hi-Z
Hi-Z
Not initialized (MTIOCnB)
Not initialized (MTIOCnD)