Product Info

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 562 of 1852
Nov 30, 2020
RX23W Group 23. Multi-Function Timer Pulse Unit 2 (MTU2a)
Figure 23.40 Example of Operation in Complementary PWM Mode
0000h
T
b2
Output waveform is active-low
6400h 0080h
6400h
6400h
0080h
0080h
Transfer from temporary register
to compare register
Transfer from temporary register
to compare register
T
a
T
b1
T
a
T
a
T
b2
MTU3.TGRA
TCDR
MTU4.TGRA
MTU4.TGRC
TDDR
Buffer register
MTU4.TGRC
Temporary register
Compare register
MTU4.TGRA
Positive-phase output
Negative-phase output
TCNTS
MTU3.TCNT
MTU4.TCNT