Product Info

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 521 of 1852
Nov 30, 2020
RX23W Group 23. Multi-Function Timer Pulse Unit 2 (MTU2a)
23.2.26 Timer Interrupt Skipping Counter (TITCNT)
Note: To clear the TITCNT counter, set the T3AEN and T4VEN bits in the TITCR register to 0.
The TITCNT counter counts the number of interrupt source occurrences for interrupt skipping. The TITCNT counter
retains the values even after stopping the count operation of counters MTU4.TCNT and MTU3.TCNT.
T4VCNT[2:0] Bits (TCIV4 Interrupt Counter)
[Clearing conditions]
When the TITCNT.T4VCNT[2:0] bits match the TITCR.T4VCOR[2:0] bits
When the TITCR.T4VEN bit is set to 0
When the TITCR.T4VCOR[2:0] bits are set to 000b
T3ACNT[2:0] Bits (TGIA3 Interrupt Counter)
[Clearing conditions]
When the TITCNT.T3ACNT[2:0] bits match the TITCR.T3ACOR[2:0] bits
When the TITCR.T3AEN bit is set to 0
When the TITCR.T3ACOR[2:0] bits are set to 000b
Address(es): MTU.TITCNT 000D 0A31h
b7 b6 b5 b4 b3 b2 b1 b0
T3ACNT[2:0] T4VCNT[2:0]
Value after reset:
00000000
Bit Symbol Bit Name Description R/W
b2 to b0 T4VCNT[2:0] TCIV4 Interrupt Counter While the T4VEN bit in TITCR is set to 1, the count in these bits is
incremented every time a TCIV4 interrupt source occurs.
R
b3 Reserved This bit is read as 0. R
b6 to b4 T3ACNT[2:0] TGIA3 Interrupt Counter While the T3AEN bit in TITCR is set to 1, the count in these bits is
incremented every time a TGIA3 interrupt source occurs.
R
b7 Reserved This bit is read as 0. R