R01UH0823EJ0110 Rev.1.10 Page 1830 of 1852
Nov 30, 2020
RX23W Group 51. Electrical Characteristics
Note: These characteristics apply when noise is not superimposed on the power supply.
Note 1. When OFS1.(LVDAS, FASTSTUP) = 11b.
Note 2. When OFS1.(LVDAS, FASTSTUP) 11b.
Note 3. The minimum VCC down time indicates the time when VCC is below the minimum value of voltage detection levels V
POR
, V
det0
,
and V
det1
for the POR/LVD.
Figure 51.69 Voltage Detection Reset Timing
Table 51.60 Characteristics of Power-On Reset Circuit and Voltage Detection Circuit (2)
Conditions: 1.8 V VCC0 = VCC_USB = AVCC0 = VCC_RF = AVCC_RF 3.6 V, VSS = AVSS0 = VSS_USB = VSS_RF = 0 V,
T
a
= –40 to +85°C
Item Symbol Min. Typ. Max. Unit Test Conditions
Wait time after
power-on reset
cancellation
At normal startup*
1
t
POR
9.1 ms Figure 51.70
During fast startup
time*
2
t
POR
1.6
Wait time after
voltage monitoring 0
reset cancellation
Power-on voltage
monitoring 0 reset
disabled*
1
t
LVD0
568 µs Figure 51.71
Power-on voltage
monitoring 0 reset
enabled*
2
100
Wait time after voltage monitoring 1 reset
cancellation
t
LVD1
100 µs Figure 51.72
Response delay time t
det
350 µs Figure 51.69
Minimum VCC down time*
3
t
VOFF
350 µs Figure 51.69, VCC = 1.0 V or
above
Power-on reset enable time t
W(POR)
1 ms Figure 51.70, VCC = below
1.0 V
LVD operation stabilization time (after LVD is
enabled)
Td
(E-A)
300 µs Figure 51.72
Hysteresis width (power-on rest (POR)) V
PORH
—110—mV
Hysteresis width (voltage detection circuit:
LVD1)
V
LVH
70 mV When Vdet1_4 is selected
60 When Vdet1_5 to Vdet1_9 is
selected
50 When Vdet1_A or Vdet1_B is
selected
40 When Vdet1_C or Vdet1_D is
selected
Internal reset signal
(active-low)
VCC
t
VOFF
t
POR
t
det
V
POR
t
det
1.0V
V