Users Manual

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 1804 of 1852
Nov 30, 2020
RX23W Group 51. Electrical Characteristics
51.3.5.6 Timing of RIIC
Note: t
IICcyc
: RIIC internal reference clock (IICφ) cycle
Note 1. The value in parentheses is used when the ICMR3.NF[1:0] bits are set to 11b while a digital filter is enabled with the ICFER.NFE
bit = 1.
Note 2. C
b
is the total capacitance of the bus lines.
Table 51.39 Timing of RIIC
Conditions: 2.7 V VCC = VCC_USB = AVCC0 = VCC_RF = AVCC_RF 3.6 V, VSS = AVSS0 = VSS_USB = VSS_RF = 0 V,
fPCLKB 32 MHz, T
a
= –40 to +85°C
Item Symbol Min.*
1,
*
2
Max. Unit
Test
Conditions
RIIC
(Standard
mode, SMBus)
SCL cycle time t
SCL
6 (12) × t
IICcyc
+ 1300 ns Figure 51.47
SCL high pulse width t
SCLH
3 (6) × t
IICcyc
+ 300 ns
SCL low pulse width t
SCLL
3 (6) × t
IICcyc
+ 300 ns
SCL, SDA rise time t
Sr
1000 ns
SCL, SDA fall time t
Sf
300 ns
SCL, SDA spike pulse removal time t
SP
01 (4) × t
IICcyc
ns
SDA bus free time t
BUF
3 (6) × t
IICcyc
+ 300 ns
START condition hold time t
STAH
t
IICcyc
+ 300 ns
Repeated START condition setup time t
STAS
1000 ns
STOP condition setup time t
STOS
1000 ns
Data setup time t
SDAS
t
IICcyc
+ 50 ns
Data hold time t
SDAH
0—ns
SCL, SDA capacitive load C
b
400 pF
RIIC
(Fast mode)
SCL cycle time t
SCL
6 (12) × t
IICcyc
+ 600 ns Figure 51.47
SCL high pulse width t
SCLH
3 (6) × t
IICcyc
+ 300 ns
SCL low pulse width t
SCLL
3 (6) × t
IICcyc
+ 300 ns
SCL, SDA rise time t
Sr
300 ns
SCL, SDA fall time t
Sf
300 ns
SCL, SDA spike pulse removal time t
SP
01 (4) × t
IICcyc
ns
SDA bus free time t
BUF
3 (6) × t
IICcyc
+ 300 ns
START condition hold time t
STAH
t
IICcyc
+ 300 ns
Repeated START condition setup time t
STAS
300 ns
STOP condition setup time t
STOS
300 ns
Data setup time t
SDAS
t
IICcyc
+ 50 ns
Data hold time t
SDAH
0—ns
SCL, SDA capacitive load C
b
400 pF