Instruction manual

Annex - Technical data
\text\etd\DA608\technical B.2 DA608 instruction manual - annex
Special functions Barcodes
- ZIP barcode (Postal barcode USA)
- Bpo4 barcode (Postal barcode Great Britain)
- 2/5 interleaved barcode
- Codabar
- Code 39
- Code 128
- EAN8 and EAN13
- KIX barcode (Postal barcode Holland)
Configuration memory for 10 settings
Test address may be loaded
Display of ink consumption
Repeat printing of up to the last 20 addresses.
Receive buffer 90K bytes
Battery buffer Printer status (last programming) is retained
even after the printer is switched off
Interfaces
parallel
Centronics compatible
serial
RS-232-C, 4800-19K2 baud
Character sets Eleven 7-bit character sets
Seven 8-bit character sets
Power connection
100V, 120V, 230V, 240V
(switchable)
50 - 60 Hz
Applies only to
printers no.
1 – 143 !!
100V, 120V, 220V, 240V
50 - 60Hz
From printer
no. 201 !!
Drive motors Stepper motor for paper transport
DC motor for printhead movement
Fuses
Line fuses (AC input)
Check serial plate!
230,240VAC: 2 x 1.6A (slow-acting)
100,120VAC: 2 x 2.5A (slow-acting)
Applies only to
printer no.
1 – 143
Verify fuse rating with
serial plate!
100,120VAC: 2 x 2A (slow-acting) From printer no.
201
Power supply
6.3A (slow-acting)
Applies only to
printer no. 1 – 143
Internal electronics
3.15A (slow-acting). Located on dot drive board.
Noise < 68 db at 1 m distance
(ISO 9296)
Certifications GS - characters
CE - characters