ZXT-120 (Z-Wave-to-AC IR Extender) Firmware Version: V1.0, V1.1, V1.2, V1.
Table of Contents Introduction .................................................... 3 Controller and Gateway Requirements ............ 4 Built-in IR code library .................................... 4 Glossary .......................................................... 5 ZXT-120 Operations ........................................ 6 Product Overview ............................................. 7 Z-Wave Remote Control ................................... 8 ZXT-120 Information ..................................
Z-ExtenderTM ZXT-120 (Z-Wave-to-AC IR Extender) Operating Instructions Introduction The ZXT‐120 is a Z‐Wave to IR extender for air‐conditioner (AC), (Figure 1), it works with any Z‐Wave compliant gateway or controller by translating Z‐Wave Thermostat Commands to AC IR control code. User can select the IR code from the built‐in code library of ZXT‐120, or use learning function, by using Z‐Wave Configuration Commands according to the parameter table.
ZXT‐120 into their Z‐Wave network using the primary controller. Then, the user can use either the primary controller or secondary controller to configure and setup the ZXT‐120 using Z‐Wave’s configuration command class. Once the configuration and setup is complete, the controller can use Z‐Wave “Thermostat commands class” to control their IR‐controlled air‐conditioner through the ZXT‐120.
Glossary Device or Node Inclusion Exclusion Remove Z‐Wave Network Primary Controller Secondary Controller Inclusion Controller Devices and nodes are all terms to describe an individual Z‐Wave device. These are all interchangeable when setting up your Z‐Wave network. Add a Z‐Wave device to the network. Delete a Z‐Wave device from the network. To take a device out of a group, scene or association group while that device still exists in the same Z‐Wave network.
ZXT‐120 Operations Before using the ZXT‐120, please read the [INSTALLATION] if you need to mount the ZXT‐120 to a wall. Power up the ZXT‐120 by the USB Power 5Vdc or Dry battery AAA x 3pcs. • • • • • • • • Plug‐in 5Vdc power into the USB socket if operated at Always Listening mode. Or Install 3xAAA batteries if operated at FLiRS mode. Please refer to the section of [MOUNTING PROCEDURE]. Remove the battery cover on the back of your ZXT‐120 battery chassis.
Product Overview Temperature sensor “PROG” Button, Learning and LED Indication Battery chassis External IR Port USB Power 5V DC Surround IR Output for top and 4-directions Figure 2 PROG Key and IR Port of ZXT-120 7
Z‐Wave Remote Control 1) 2) 3) 4) 5) Select your operation mode; please refer to “Listening Mode” section. Include or Exclude the unit from the existing Z‐Wave home control network with your primary controller. ‐ Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. ‐ When prompted by your primary controller, click once on the PROG button. ‐ The primary controller should indicate that the action was successful.
ZXT‐120 Information How to get the NIF “Node Information Frame” on ZXT‐120 (Inclusion) Step Setup Key Press the PROG button on the ZXT‐120 1 LED Indication Status on ZXT‐120 • LED flashes once then stay off (ZXT‐120 will report the supported command class) Parameter No.
33 (0x21) 35 (0x23) 37 (0x25) air‐conditioners in a room are used - extend the battery life by disabling the Surround IR Emitters AC function “SWING” control (default) 0x00: SWING OFF 0x01: SWING AUTO (Default) Learn location status Bit mask = 1, learn location has learn data. Otherwise, Bit mask = 0 See figure “Learn location” as below On below example, location 1, 7, 8, 12, 16 are learned data.
o 0xFF = ‐1 C o 0xFE = ‐2 C o 0xFD = ‐3 C o 0xFC = ‐4 C o 0xFB = ‐5 C Parameter Table L Mapping Information − − BASIC Set Value 0x00 will map to Thermostat mode Off 0x00. BASIC set Value 0xFF will map to Thermostat mode Resume 0x05. Listening Mode Change (default mode is FLiRS) ZXT‐120 can be configured as either “Frequently Listening Routing Slaves” (FLiRS) or “Always Listening” node after exclusion process.
OR • LED flashes four times then stay off (ZXT‐120 set in Always Listening mode) IR Code Selection ZXT‐120 is with built‐in IR AC code library, user may select the IR code using Configuration Command Class. LED Indication Status on ZXT‐120 Step Setup Key After included ZXT‐120 to Z‐Wave controller or Gateway, go to device setup for configuration on gateway or controller. ‐ 1 ‐ 2 Input parameter number “27” and parameter value (please look up the code list of ZXT‐120 according to your AC brand).
L Important Information − Different brand or model of air conditioner has different function. For example, some air conditioner only support o o o temperature set from 18 C‐30 C, if user set 17 C on gateway, ZXT‐120 will not respond. − There are more than 1 code for each brand, some does not support heat, if user selected a code that does not support heat but the original air conditioner supports heat function, please continue to try next code until the correct one is selected.
parameter value “5” (in this case). 4 Press the PROG button on the ZXT‐ 120. (this step apply when using ZRC‐100 or other portable controller for set up, if using gateway, user can skip this step) • LED flashes once when ZXT‐120 receives the configuration setting • ZXT‐120 is ready to learn Aim the original air conditioner remote at ZXT‐120 according to below position within 1‐3 inches LED flashes twice if learning is successful. LED flashes 6 times if it’s failed.
IR Learning Mapping Table (Parameter number 25) Parameter Value (Location) Thermostat command & IR setting 0 OFF 1 ON (resume) 2 19°C cool 3 20°C cool 4 21°C cool 5 22°C cool 6 23°C cool 7 24°C cool 8 25°C cool 9 26°C cool 10 27°C cool 11 28°C cool 12 19°C heat 13 20°C heat 14 21°C heat 15 22°C heat 16 23°C heat 17 24°C heat 18 25° C heat 19 26°C heat 20 27°C heat 21 28°C heat 22 Dry mode 15 Default Cool Default Heat
L Important Information After all learning completed, user can go back to the ZXT‐120 control page on the gateway for normal operation. − On the gateway UI, user can only use the temperature range from the mapping table, OFF, ON(RESUME), COOL, HEAT, DRY, If user press the button of FAN, or other function on the gateway UI which is not listed in above table, ZXT‐120 will not respond.
Reset ZXT‐120 to factory default Press and hold “PROG” button for 10seconds on ZXT‐120. The LED will flash twice until reset process is completed. Note: This reset step will not affect the operation mode of ZXT‐120, user should refer to “Listening Mode" section if you want to change the operation mode. L Information − If you are using Gateway or other Z‐wave controllers to operate ZXT‐120, Please follow the instruction from the gateway or other controller.
INSTALLATION MOUNTING THE ZXT‐120 TO A WALL MOUNTING LOCATION PRECAUTIONS • Before mounting, check the material and structure of the mounting location. If the location does not have the proper material or structure, the ZXT‐120 can fall and cause injuries. • Use commercial items that best match the wall structure and material for the screws and other fixtures. • Do not mount near a kitchen counter, humidifier, or other location in which it can be exposed to smoke or steam.
Note 2: Before mounting to a wall, be sure to fully read the precautions. 1. Obtain two screws suitable for the wall strength and material. The screw size is shown in the figure below. 2. The positional relationship between the ZXT‐120 key holes and the screw mounting positions are shown in the figure below. Note 1: When mounting the screws to the wall, leave a space between the wall and screw cap as shown in the figure. 3.
Note 1: Check that the ZXT-120 is firmly secured to the wall. Note 2: Insert USB plug or batteries and IR emitter cable so that they are firmly connected to the ZXT-120. 5. When removing the ZXT‐120 from the wall, lift up the ZXT‐120, then pull it towards you. 6. Detach the main unit from the battery chassis by move toward to top position.
WIRELESS INFORMATION Wireless range: This device has an open‐air line‐of‐sight transmission distance of 100 feet which complies with the Z‐Wave standards. Performance can vary depending on the amount of objects in between Z‐Wave devices such as walls and furniture. Every Z‐Wave device set up in your network will act as a signal repeater allowing devices to talk to each other and find alternate routes in the case of a reception dead spot. Radio frequency limitations: 1. Each wall or object (i.e.
Q Can I use the USB port to configure ZXT‐120? A No, the mini USB port only provides an alternative option for user to power the ZXT‐120. Q A Do I need an electrician to install Z‐Wave products in my house? Installation can be simple. In some cases all you need to do is mount the ZXT‐120 to a wall or wooden racks. You also can place the ZXT‐120 on the desk and power it with dry cell batteries.
Q A Where can I keep up to date with the latest Z‐Wave products for my house? You can keep up to date by visiting the www.remotec.com.hk website where we will have information and ideas for using Z‐ Wave technology. TECHNICAL SPECIFICATIONS Model no. RF frequency RF operating distance IR operating distance IR learning Temperature Powered by Dimension Weight BW8377EU (ZXT‐120EU) BW8377AU (ZXT‐120AU) BW8377US (ZXT‐120US) BW8377IN (ZXT‐120IN) 868.4MHz (EU) (ZXT‐120EU) 921.4MHz (AU) (ZXT‐120AU) 908.
COMMAND_CLASS_BATTERY Version1 NO YES COMMAND_CLASS_CONFIGURATION Version1 NO YES COMMAND_CLASS_BASIC Version1 NO YES COMMAND_CLASS_VERSION Version1 NO YES COMMAND_CLASS_SENSOR_MULTILEVEL Version1 NO YES COMMAND_CLASS_SWITCH_ALL Version1 NO YES COMMAND_CLASS_MANUFACTURER_SPECIFIC Version1 NO YES Supported function in Thermostat Command Class Z‐Wave command class Description Supported Auto/Auto Low YES Low YES Auto High YES High YES Auto Medium YES Medium YES Heatin
Dry Air YES Moist Air NO Auto Changeover YES Energy Save Heat NO Energy Save Cool NO AWAY NO ZXT‐120 functions and Parameters summaries: AIR FUNCTIONS CONDITIONER Z-WAVE COMMAND COMMAND PARAMETER Z-WAVE COMMAND CLASS FUNCTION COMMAND_CLASS_THERMOSTAT THERMOSTAT_ _MODE MODE_SET COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_THERMOSTAT THERMOSTAT_ _MODE MODE_SET COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_THERMOSTAT THERMOSTAT_ _MODE MODE_SET COMMAND_CLASS_THERMOSTAT THERMOSTA
THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN MODE = 0, 2, or FAN_MODE_SE _FAN_MODE, v2 4 T THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN_MODE_SE FAN MODE = 1 _FAN_MODE, v1 T FAN LOW (1/3) THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN_MODE_SE FAN MODE = 1 _FAN_MODE, v2 T FAN MID (2/3) - - THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN_MODE_SE FAN MODE = 5 _FAN_MODE, v2 T THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN_MODE_SE FAN MODE = 3 _FAN_MODE, v1 T FAN HIGH (3/3) THERMOSTAT_ COMMAND_CLASS_THERMOSTAT FAN_MODE_SE F
VALUE = 0 PARAMETER NO.
CHECKING ACCESSORIES After opening the cover of the packing box, check that the following accessories are included. • ZXT‐120 (Z‐Wave‐to‐AC IR Extender) • Screws (bottom cover) x 2pcs • ZXT‐120 User Manual (download from our website) • AC Code List (download from our website) FCC NOTICE This device complies with Part 15 of the FCC rules.
WARRANTY ONE‐YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributor or dealer.