Specifications
34
Sensortemperature
calibration
(Thisparameterisusedto
changethedisplay
temperaturetomatchwith
yourpreviousthermostat,or
tomatchanother
thermostatalreadyinyour
home.
13(0x0D)
Tempe ratureoffsetvalue.
Formula:
Displaytemperature=sensorreading
value+offsetvalue
(unit=degreeF)
0(0x00)=
0
o
F(Default)
1(0x01)=1
o
F(0.5
o
C)
2(0x02)=2
o
F(1.0
o
C)
3(0x03)=3
o
F(1.5
o
C)
4(0x04)=4
o
F(2.0
o
C)
5(0x05)=5
o
F(2.5
o
C)
6(0x06)=6
o
F(3.0
o
C)
7(0x07)=7
o
F(3.5
o
C)
8(0x08)=8
o
F(4.0
o
C)
9(0x09)=9
o
F(4.5
o
C)
10(0x0A)=10
o
F(5.0
o
C)
‐1(0xFF)=‐1
o
F(‐0.5
o
C)
‐2(0xFE)=‐2
o
F(‐1.0
o
C)
‐3(0xFD)=‐3
o
F(‐1.5
o
C)
‐4(0xFC)=‐4
o
F(‐2.0
o
C)
‐5(0xFB)=‐5
o
F(‐2.5
o
C)
‐6(0xFA)=‐6
o
F(‐3.0
o
C)
‐7(0xF9)=‐7
o
F(‐3.5
o
C)
‐8(0xF8)=‐8
o
F(‐4.0
o
C)
‐9(0xF7)=‐9
o
F(‐4.5
o
C)
‐10(0xF6)=‐10
o
F(‐5.0
o
C)
Exampleforsensortemperaturecalibration:readingtemperature(77
o
F)+(‐2
O
F)
Functions ParameterNumber Parametervaluerange
Sensortemperature
calibration
13(0x0D)
‐2(0xFE)=‐2
o
F(‐1.0
o
C)
Ifusingdecimalinput
Parameterno.=13 Parametervalue=‐2
Ifusinghexadecimalinput
Parameterno.=0D Parametervalue=FE(Size>=1byte)
Displaytemperature =sensorreadingvalue+offsetvalue
=77‐2
o
F=75
o
F