Specifications
30
Exclusioniscompleted.
4
Press “Home" keyoncetogo
backtothehomepage.
willdisappearonthemain
display
SupportforAssociationGroups
ZTS‐110supports3associationgroups.
Associationgroup_1
(Heatpump)
Associationgroup_2
(Compressor)
Associationgroup_3
(AutoReport)
Heatingmode
ON
(basicsetcommand0xFF)
OFF
(basicsetcommand0x00)
‐
Coolingmode
OFF
(basicsetcommand0x00)
ON
(basicsetcommand0xFF)
‐
OFF
OFF
(basicsetcommand0x00)
OFF
(basicsetcommand0x00)
‐
Associationgroup_3: (Autoreport)
z Associationgroup_3isusedtoreportstatuschangetogateway .
(Onlygatewayorcontrollercanbeassignedinthisassociationgroup)
ZTS‐110willtriggerAUTOreportfunctionifoneofbelowstatusischanged.
I. Operationmode(Off,Heat,Cool,Auto)
II. Operationstate(Heatonoroff,Coolon
oroff)
III. Fanmode(Auto,Autolow)
IV. Fanstate(FanonorFanoff)
V. Heatsetpoint(reportinprecision1afterdecimal,e.g.21.1
o
C)
VI. Coolsetpoint(reportinprecision1afterdecimal,e.g.23.3
o
C)
VII. Currentroomtemperature(reportinprecision1afterdecimal,e.g.24.0
o
C)
(Itwilltriggerroomtemperaturereportifthereis4
o
For2
o
C(default)differfromlastreport.
Youcanchangethissettingbysettheconfigurationparameter)
Mode
Associationgroup