ShortCycleStartUpProtection
Toprotectthecompressor/Heatpump,thoseoutputsforcedoffuntil3minutescountdown
finished.Thoseoutputscanbeactivatedaccordingtotheroomtemperatureafter3minutes.
System Output
NonHeatpumpsystem Compressor
Heatpumpsystem 1ststageheatandcompressor
EnergySavingMode
Step Procedure/Description LCDindication
1
Usercanenable/disableenergy
savingmodebyusingZWave
BASICsetcommandonly.(youmay
refertotheZWaveprimar y
controllerUIforit)
=>Enableenergysavingmode
Basicsetvalue=0x00(Off)
(energysavingmodewillbemapped
tooffmode)
=>Disableenergysavingmode
Basicsetvalue=0xFF(Resume)
(comfortmodewillmappedto
resumemode)
ZWaveSetupandOperations
SettingFLiRSorAlwaysListeningmode
SettingtoZWaveFLiRSmodewithbatteriesaspowersource
ZTS110willselfconfiguretoFLiRSmodeifitispoweredbybatteriesorpoweredbybatteriesfirst
then applied with 24Vac before ZWave inclusion. FLiRS mode is targeted for battery operat ed
applicationsandwillentersleepmodefrequentlyinordertosavebatterylife.ZTS110can’tact
as
a repeater in this mode. The response to ZWave command is not as quick as Always Listening
Device.Normallythereis12secondslatencyonresponse,youshouldavoidsendingcommandsto
ZTS110toofrequently.

SettingtoZWaveAlwaysListeningmodewith24Vacaspowersource
ZTS110willselfconfiguretoAlwaysListeningModeifitispoweredby24Vacorpoweredby24Vac
firstthenappliedwithbatteriesbeforeZWaveinclusion.AlwaysListeningmodeistargetedforAC
power operated applications and it can act as a repeater which will retransmit the RF
signal to
ensurethatthesignalisreceivedbyitsintendeddestinationbyroutingthesignalaroundobstacle
andradiodeadspots.TheresponsetoZWavecommandisimmediate.