User's Manual

16
Note:
All the above Parameter Number and Value is in Hexadecimal Numbering Format,
if the Gateway only support decimal numbering format, please change it to deci-
mal value accordingly.
Mapping Information
BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00
BASIC Set Value 0xFF will map to Thermostat mode Resume 0x05
Energy Saving Mode will map to Thermostat mode OFF
Comfort Mode will map to Thermostat mode Resume 0x05
Support for Association Groups
ZXT-600 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate with the
primary controller (Gateway/Hub/Controller) for AC Master Status
change report, refer to below for report details:
Current Room Temperature (report in precision of 0.5°C or 1°F)(It
will be according to Conguration Parameter 39 setting to decide
the trigger level)
Current Battery Level (Only apply in Low Battery Warning hap-
pened)
Device Reset Locally Notication (Only report when the AC Master
has been triggered the RESET TO DEFAULT)