User's Manual
Table Of Contents
16
Note:
All the above Parameter Number and Value is in Hexadecimal Numbering Format,
if the Gateway only support decimal numbering format, please change it to deci-
mal value accordingly.
Mapping Information
• BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00
• BASIC Set Value 0xFF will map to Thermostat mode Resume 0x05
• Energy Saving Mode will map to Thermostat mode OFF
• Comfort Mode will map to Thermostat mode Resume 0x05
Support for Association Groups
ZXT-600 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate with the
primary controller (Gateway/Hub/Controller) for AC Master Status
change report, refer to below for report details:
• Current Room Temperature (report in precision of 0.5°C or 1°F)(It
will be according to Conguration Parameter 39 setting to decide
the trigger level)
• Current Battery Level (Only apply in Low Battery Warning hap-
pened)
• Device Reset Locally Notication (Only report when the AC Master
has been triggered the RESET TO DEFAULT)