User's Manual
30
2 (0x02) = Level-2 (middle) , default
3 (0x03) = Level-3 (bright)
Sleep timer 12 (0x0C) 3 (0x03) to 60 (0x3C) seconds,
255 (0xFF) = Always On
Step size = 1s,
Batt = 5s, default
24Vac = 60s, default
Repeat basic set counter
(Association Group A and B
only)
13 (0x0D) Value(X)
0 (0x00), 3 (0x03) to 255 (0xFF)
0 (0X00) = Disable, default
3 (0x03) to 255 (0xFF) minutes
(Thermostat sends “Basic Set” command to
its association node repeatedly in every X
minutes)
Trigger AUTO report if room
temperature is different from
last report.
(It will report room
temperature only)
*User can use this function to
enhance batteries service life.
14 (0x0E) 0 (0x00) = disable AUTO report if room
temperature is different from last report.
AUTO report if room temperature is different
from last report.
Delta change is >=
1 (0x01) = 1
o
F (0.5
o
C), default value if
powered by 24Vac
2 (0x02) = 2
o
F (1.0
o
C), default value if
powered by battery
3 (0x03) = 3
o
F (1.5
o
C)
4 (0x04) = 4
o
F (2.0
o
C)
5 (0x05) = 5
o
F (2.5
o
C)
6 (0x06) = 6
o
F (3.0
o
C)
7 (0x07) = 7
o
F (3.5
o
C)
8 (0x08) = 8
o
F (4.0
o
C)
AUTO report by time interval.
(It will report room
temperature only)
*User can use this function to
enhance batteries service life.
15 (0x0F) 0 (0x00) = disable AUTO report function (by
time interval), default
AUTO report timer:
1 (0x01) = 0.5 hr
2 (0x02) = 1.0 hr
3 (0x03) = 1.5 hrs
4 (0x04) = 2.0 hrs
5 (0x05) = 2.5 hrs
6 (0x06) = 3.0 hrs
7 (0x07) = 3.5 hrs
8 (0x08) = 4.0 hrs