User's Manual
27
f) Cool set point (report in precision of 0.5
o
C or 1
o
F)
g) Current room temperature (report in precision of 0.5
o
C or 1
o
F)
(It will trigger room temperature report if there is 2
o
F / 1
o
C [default] differ from last report.
You can change this setting by set the configuration parameter)
Notes:
Total 5 devices (nodes) can be assigned in total 3 association groups. Below table lists out the devices
(nodes) allocations in the 3 association groups.
No. of Node ID in
Association Group_1
No. of Node ID in
Association Group_2
No. of Node ID in
Association Group_3
1 (AUTO report) 0,1 or 2 nodes 0,1 or 2 nodes
Important:
Please do not associate heater and compressor devices in same association group because heater and
compressor device can’t turn on in simultaneously!
Example: Association groups setting
F-BW8170 (ZTS-500US)
F
-
BW8041 (ZFM
-
80)
(Node ID
-
B
)
F
-
BW8041 (ZFM
-
80)
(Node ID
-
C
)
Z
-
Wave Gateway
(Node ID
-
A
)
Association group_
2
for Heater
Association group_
3
for Compressor
Association group_
1
for Auto report to gateway
F
-
BW8041 (ZFM
-
80)
(Node ID
-
D
)
F
-
BW8041 (ZFM
-
80)
(Node ID
-
E
)