Operating instructions
21-1780-7D001/E-05/2013-BEH-D278563
HSB
Type Rated
voltage
Operation
voltage
Max. pipe
temperature
Max.
temperature
Temperature T-class Temperature
07-5803-110 A 120 V
impressed voltage
Max. pipe (exposure) temperature of design documents
T3 195 °C
07-5803-115 A 120 V T3 195 °C
07-5803-125 A 120 V T3 195 °C
07-5803-130 A 120 V T3 195 °C
07-5803-145 A 120 V 200 °C T2 200 °C
07-5803-160 A 120 V 200 °C T2 200 °C
07-5803-210 A 254 V > 105 °C T3 195 °C
07-5803-210 A 254 V ≤ 105 °C T4 130 °C
07-5803-215 A 254 V > 170 °C T3 195 °C
07-5803-215 A 254 V ≤ 170 °C T4 130 °C
07-5803-225 A 254 V > 155 °C T3 195 °C
07-5803-225 A 254 V ≤ 155 °C T4 130 °C
07-5803-230 A 254 V > 125 °C T3 195 °C
07-5803-230 A 254 V ≤ 125 °C T4 130 °C
07-5803-245 A 254 V T3 195 °C
07-5803-260 A 254 V ≤ 120 °C T3 195 °C
MSB
Type Rated
voltage
Operation
voltage
Max. pipe
temperature
Max.
temperature
Temperature T-class Temperature
All 254 V
impressed voltage
≤ 110 °C
Max. pipe (exposure) tempera-
ture of design documents
150 °C T3 150 °C
MSB 10 254 V ≤ 100 °C T4 130 °C
MSB 15 254 V ≤ 190 °C T4 130 °C
MSB 25 254 V ≤ 180 °C T4 130 °C
MSB 30 254 V ≤ 170 °C T4 130 °C
MSB 40 254 V ≤ 160 °C T4 130 °C
EN 8/16
HSB and MSB Operating instructions
1
46
2 3
1
4
6
2
3
5
Protection device 16 A, 20 A, 25 A, 32 A/C- Characteristic
7
Frequency 50 or 60 Hz
8
Construction and week/year 15/2009 (for example)