Operating instructions
21-1780-7D001/E-05/2013-BEH-D278563
Reservation
Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages.
EN 5/16
Self-limiting heating tapes HSB and MSB
Type selection Description
05-0091-0129 Single HSB Cold applied set for direct connection (on enclosure) and end termination (Silicone)
05-0091-0135 Tenfold package HSB Cold Applied Set for direct connection (on enclosure) and end termination (Silicone)
05-0091-013501 Tenfold HSB Connection Set without end cap, Cold Applied Set (Silicone)
05-0091-013502 Tenfold HSB Termination Set, Cold Applied Set (Silicone)
05-0091-013503 Fiftyfold HSB Connection Set without end cap, Cold Applied Set (Silicone)
05-0091-013504 Fiftyfold HSB Termination Set, Cold Applied Set (Silicone)
þ Documents:
Operations and mounting manual self-limiting heating tapes
MSB 01-5804-7D0001
Operations and mounting manual self-limiting heating tapes …
HSB… and self-limiting heating tapes…03-0390-0042
This manual for cold applied connection and termination
kits 21-1780-7D0001
Operation and mounting manual PLEXO connection and termination
kits 21-1780-7D0003
6. Operation, maintenance and fault clearance
The heating systems must be used only in accordance with their
intended purpose and within the operating data specified by BARTEC.
The operator of an electrical system in a hazardous environment must
keep it in good condition, operate it properly within the limits of the
certificate, monitor it and do maintenance and repairs. (IEC/EN 60079-
14 and IEC/EN 60079-17). Only an electrician may do the maintenance
work and fault clearance.
Before re-starting operation, check compliance with the applicable laws
and directives. Before maintenance or troubleshooting, make sure that
the specified safety regulations are adhered to.
Don´t touch the surface of the BARTEC HSB type 07-5803-
***A or MSB type 07-5804-2**X or type 07-5804-2**Y while
these are energized. First-/second-/third-degree burn can
occur. Don´t touch also the heated areas. Warning signs shall
be installed.
Only use parts of origin.
7. Accessories and Equipment see BARTEC catalogue
Max-Eyth Straße 16
97980 Bad Mergentheim
Deutschland
Phone: +49 7931 597-0
Fax: +49 7931 597-119
info@bartec.de