2.4 General warnings, cautions and notes
Tempus Pro User/Operator Manual - 41-2001EN-00 – Page 19
WARNING
Do not disassemble
the device. The device must only be serviced by trained and
authorised biomedical engineers following RDT approved procedures and using parts
provided by RDT. Any other changes or processes are unauthorised and should not
be performed. No other modifications are allowed. Unauthorised processes, repairs,
modifications, reworks or service not expressly approved by RDT could void any
guarantees and warrantee and could be hazardous. Do not modify this device
without authorisation from RDT. If the device is modified, appropriate inspection and
testing must be conducted to ensure continued safe use of the device.
CAUTION
The Tempus may be used on ambulances or on vehicles using radios. As detailed in
section 14.5, it has been tested to determine operation in field strengths greater than 3V/m.
Users are advised to maintain the best distance possible between radio antennas and the
Tempus as best practice.
CAUTION
This device is intended for use by persons trained in professional health care. The operator
must be thoroughly familiar with the information in this manual before using the device.
CAUTION
The Tempus Pro may not operate correctly if used or stored outside the relevant
temperature or humidity ranges described in the performance specifications of this manual.
CAUTION
Only use only approved accessories supplied by RDT. Conventional 4mm snap-on, pre-
gelled ECG electrodes may be used so long as they comply with AAMI EC12. Users are
reminded to read and adhere to the instructions for such electrodes including noting single
use only status, maximum usage times and patient indications.
CAUTION
Do not clean the Tempus or its accessories except as directed in this guide.
CAUTION
In the event that the device displays an error that is not described within this manual e.g.
applications errors, turn the device off and then on again. This should clear the error and
allow normal operation to resume. Do not continue to use the device if such an error is
displayed. If symptoms persist, please contact RDT.
CAUTION
The Tempus records all data that it measures. In order to ensure that data from different
patients is not confused, the device must be switched off between taking readings from
different patients or the patient discharge function used.
CAUTION
Should the device become wet, wipe off all moisture and allow sufficient time for drying
before operating. Take care to ensure that water or liquids are not spilt over the device or
into its ventilation holes in the side corners.
CAUTION
If the accuracy of any measurement is in question, verify the patient's vital sign(s) by an
alternative method and then check the monitor for proper functioning.
CAUTION
Follow local government regulations and recycling instructions regarding disposal and
recycling of device and device components.
CAUTION
The Tempus Pro and its accessories use different types of batteries which includes
rechargeable and non-rechargeable types. If any battery fails to hold a charge or otherwise
becomes inoperable, the battery should be replaced and the old battery should be disposed
of properly.