Operating Guide
©2017 Pinnacle Climate Technologies 23 Vent-Free Gas Heater User’s Manual
Operation (cont.)
INSPECTING BURNERS
Check the pilot ame pattern and burner ame patterns often.
PILOT FLAME PATTERN
Figure 20 shows a correct pilot ame pattern. Figure 21 shows an incorrect pilot ame pattern. The
incorrect pilot ame is not touching the thermocouple. This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down. If pilot ame pattern is incorrect, as shown in Figure 21:
• Turn the heater o (see TO TURN OFF GAS TO THE HEATER, pages 21–22).
• See the TROUBLESHOOTING GUIDE, page 25.
Fig. 20—Correct Pilot Flame Pattern Fig. 21—Incorrect Pilot Flame Pattern
Do not allow fans to blow directly into the heater. Avoid any drafts that alter
burner ame patterns.
WARNING