Operating Guide

©2017 Pinnacle Climate Technologies 12 Vent-Free Gas Heater Users Manual
Installation (cont.)
HEATER CLEARANCES
For convenience and eciency, install the heater with these points in mind:
Provide easy access for operation, inspection and service.
Install the heater in the coldest part of the room.
If this heater is installed directly on carpeting, tile, or other combustible material, other than wood ooring,
the heater must be installed on a metal or wood panel that extends the heaters full width and depth.
Clearances to Combustibles:
Carefully follow the instructions below. This heater can be mounted on the wall or on the oor using
the support legs (select models).
If you install the heater in a home garage, a.) ensure the heater pilot and burner are at
least 18" above the oor and, b.) locate the heater where moving vehicles will not hit it.
Maintain the minimum clearances shown in (see Fig. 3). If you can, provide greater
clearances from oor, ceiling, and joining wall.
WARNING
Fig. 3—Mouting Clearances as Viewed from the Front of
the Heater (Inches)
CEILING
RIGHT SIDE
LEFT SIDE
FLOOR
FRONT
8"
Minimum
from
Side of
Heater
36"
Minimum
36" Minimum from
Furniture and Draperies
3" Minimum to Top Surface of Carpeting,
Tile, or Other Combustible Material
Minimum Clearance to Combustibles
*Left / Right Top Bottom Front Rear
8 in. 36 in. 3 in. 36 in. 0 in. to Spacer
Top clearance is from the top of the heater to the ceiling, wood shelf, or other combustible material.
Bottom clearance is from the bottom of the heater to the surface of carpet, tile, or other combustible material.
*A second side wall must be at least 18 in. away from the other side of the heater. Always maintain a
minimum of 36 in. clearance from furniture and draperies.
*For the installation in residential garages, refer to the CAUTION statement above.