Technical data

8
Conventional flue
CLV system
(twin pipe - two zone)
For further options see flue booklet.
- Please note that the maximum flue length is calculated on the flue diameter stated.
Flue lengths will be increased using larger diameter flue pipe.
- Please contact our technical department for assistance if required.
Calculation data – conventional flue
Calculation data – different pressure zones
Bird guard and reduction cone
Bird guard and reduction cone
Bird guard
Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115
80mm 80mm 100mm 100mm 100mm
max eq. length m 40 33 27 24 19
eq. length bend 45° m 1.2 1.2 1.4 1.4 1.4
eq. length bend 90° m 4 4 4.9 4.9 4.9
Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115
80mm 80mm 100mm 110mm 125mm
max eq. length m 20 28 18 22 58
eq. length bend 45° m 1.2 1.2 1.4 1.5 1
eq. length bend 90° m 4 4 4.9 5.4 1.7