Operation Manual
31
EN
Fault indication Green status LED flashes as follows:
Problem No connection with
iSense RF.
Solution
- Check whether the iSense RF indicates a fault or is on.
- Try to re-establish the connection between the iSense RF and
the Base station; see Chapter 5.
- If this does not solve the problem, relocate the iSense RF or the
Base station
or remove obstacles that can interfere with the RF
signal; see paragraph 3.1.
Fault indication Green LED flashes as follows:
Problem Power problem
Solution
Check whether the boiler is on and whether the
Base station is
correctly connected. If the boiler does not support OpenTherm Smart
Power, then connect an external (5
V DC 300mA) adapter.
Fault indication Green LED flashes as follows:
Problem There is no OpenTherm communication for 60 seconds.
Solution
- Check whether the boiler is on and whether the Base station is
correctly connected.
tabel 02
Fault indications green status LED