4.2 Switching Times
4.2.1 Programming switching points
Each Channel has 16 programmable Switching Points (8 x
ON, 8 x OFF):
Nos. 1, 3, 5, 7, 9, 11, 13, 15 are Switch ON points
(lamp symbol ☼).
Nos. 2, 4, 6, 8, 10, 12, 14, 16 are Switch OFF points
(no symbol).
The Switch Time selected will be indicated by a number in the
lower right of the Display and the lamp symbol ☼.
The Channel number will be indicated above right.
62432.LT.AL.REM.003
2 Channel nr.
1 Switching point
12
1
2
34567
62432.LT.AL.REM.004
2 Channel nr.
2 Switching point
12
2
34567
2
Please note when programming:
Each switch ON point is closely linked to the following switch
OFF point
Switch-point 1: switch ON
Switch-point 2: switch OFF
Switch-point 3: switch ON
Switch-point 4: switch OFF
Etc.
They should always be programmed in pairs to avoid errors.
z
The shortest possible switching interval is 1 minute.
4.2.2 Setting the Switch ON Point
Proceed as follows:
• Set the right sliding switch to position P1 (Channel 1, CH)
or P2 (Channel 2, DHW). The first switch point (switch ON)
is displayed.
• Press button „1...7“ to input the day of the week or blocks
of days.
• Continuous pressing of this button allows you to select indi-
vidual days and the following blocks of days:
Press once: Day 1 (Monday)
Press twice: Day 2 (Tuesday)
Press three times: Day 3 (Wednesday)
Press four times:: Day 4 (Thursday)
Press five times: Day 5 (Friday)
Press six times: Day 6 (Saturday)
Press seven times: Day 7 (Sunday)
Press eight times: Block 1 to 5 (Monday to Friday)
Press nine times: Block 6 to 7 (Saturday to Sunday)
Press ten times: Block 1 to 6 (Monday to Saturday)
Press eleven times: Block 1 to 7 (Monday to Sunday)
o Arrows in the Display indicate days of the week.
• Press buttons „h“ and „m“ to set the time.