Technical data
6
remeha W40/60-m ECO
modulating
high - low
on - off
18.2
60.5
20.3
66.4
20.7
69.0
18.6
62.1
II
2H 3P
17 - 30
2.0 - 6.6
18
10
0,8
104
B23, C13, C33,
C43, C53, C63
240/50
100
2
20
100
20 - 90
0.3
3
6
900
not applicable
75
3.2 Technical data
Boiler type
Load control: adjustable
Output (80/60˚C) - min.
- max.
(40/30˚C) - min.
- max.
Input (GCV) - min.
- max
Input (NCV) - min.
- max
Category
Inlet pressure gas
Gasrate (natural gas)
NOx emission
Residual fan duty
Mass flue rate
Appliance (flue) type
Main supply
Electric rating
Fuse rating
Isolation class
Watertemperature - max.
- control
Operating pressure - min.
- max.
Water contents
Waterresistance (∆T = 10˚C)
Residual pump duty (∆T = 20˚C)
Assembly weight
modulating
high - low
on - off
12,4
41.0
14.0
44.3
14.1
47.0
12.7
42.3
II
2H 3P
17 - 30
1.3 - 4.5
51
29
0,8
71
B23, C13, C33,
C43, C53, C63
240/50
150
2
20
100
20 - 90
0.3
3
5
400
350
67
kW
kW
kW
kW
kW
kW
kW
kW
mbar
m
3
/h
mg/kWh
ppm
mbar
kg/h
V/Hz
VA
A
IP
°C
°C
bar
bar
ltr
mbar
mbar
kg
remeha
W40-m ECO
remeha
W60-m ECO
3.3 Delivery package
- circulation pump
- low loss header
- pressure gauge
- filling and drain cock
- air supply fan
- electronic control and protection equipment: 24V
- interface for
rematic
®
weather-compensated boiler
control
- temperature regulation: adjustable from 20 to 90°C
- differential air pressure switch
- low-water protection via temperature sensors
- aluminium heat exchanger
- red spray-coated sheet steel casing
- pump switch
- frost protection
- easy-to-read control panel with display
- siphon trap
- hanging bracket
- automatic vent.
Accessories
- conversion set for propane
- connection set for calorifier
- outdoor temperature sensor
- modulating
rematic
®
weather-compensated boiler
control
- interface for modulating room control (Honeywell
Chronotherm Modulation).