Specifications
RMU800A SERVICE MANUAL 
- 135 - 
Receiver 
Measurement Adjustment 
Item Condition 
Test Instrument  Terminal Part  Method 
Specification 
/Remarks 
15.RF bandpass 
filter 
Enter adjustment item 
“10”, 
each Ch corresponds to a 
specific RX Freq   
Scanner ANT. TP1
Adjust 
software 
settings
A
djust the gain to 
the Max. value, the 
corresponding freq 
is on the left most 
to bandpass 
waveform. Press 
[PF6] to save. 
16.IF bandpass 
filte 
Center Freq is 73.05MHz 
Scanner 
Adjust 
L107、
TC101、
L151、
L108、
TC102、
L150。 
A
djust 
L107.TC101.L151 
(narrow); L108 、
TC102、L150(wide)
17.max SINAD 
CH: 
 RX  Center ,  turn to 
CH1(C); corresponds to a 
specific RX Freq 
Radio 
Communication 
Test Set 
 SSG output: 
-47dBm 
MOD:1KHz 
DEV:±3KHz(W)
 ±1.5KHz(N) 
FILTER: 
0.3-3.0KHz 
ANT 
SP Jack
L135 
A
djust the L135 to 
maximize SINAD 
The max volume :
4.6V or higher 
1.CH: RX Center, turn to 
CH1(C) in manual adjust 
mode 
2. CH: RX LO, 
turn to CH2(L) in manual 
adjust mode 
18. Sensitivity 
3.CH:RX HI, 
turn to CH3(H) in manual 
adjust mode 
Radio 
Communication 
Test Set 
 SSG output: 
-116dBm 
MOD:1KHz 
DEV:±3KHz(W)
 ±1.5KHz(N) 
FILTER: 
0.3-3.0KHz 
ANT 
SP Jack 
W/N switch
(turn on 
power while 
holding 
down [PF6] 
to enter 
Channel 
Set Mode)
[UP]/ [DOWN] to 
change channel   
Check 
SINAD: 
12dB or higher