  When the Function is On (press PF4, ▽ appears) 
Controls  Function  Description 
PF1 Compander on/off. 
When compander opens,  ▼ appears. 
PF2  Beat shift on/off. 
When the remove frequency is on, “A” appears. 
PF3  MSK 1200/2400bps changeover. 
When MSK is 2400bps,“
” appears. 
PF4  Return to test mode.   
PF5 No function.   
PF6 No function.   
1-3 Panel Tuning Mode 
Controls  Function  Description 
Up 
Volume up. 
Down 
Volume down. 
PF1 
Test mode/tuning mode changeover. 
PF2 
Noise squelch switch. 
When the squelch is on,   appears. 
PF3 
No function. 
PF4 
Tuning item down. 
PF5 
Tuning item up. 
PF6 
Tuning value save and then move to the next 
tuning item. 
Selector Knob 
Tuning value up/down. 
2. Panel Test Mode   
The transceiver’s transmission output, receiver sensitivity, and other items are measured and QT, DQT, 
2-Tone, MSK and DTMF signalling is decoded in this mode. 
2-1. To Enter the Test Mode 
Hold down [PF2] key and turn the power switch on to enter test mode. The test frequency channel and 
test signalling channel will be displayed. 