User's Manual
Table Of Contents
- Introduction
- FCC Requirements
- Industry Canada Compliance
- Information and Options
- Radio Controls
- LCD Touch Screen
- Microphone Controls
- Function Selection
- Channel/Zone Selection Options
- Basic Operation
- Trunking Channel Basic Operation
- Command Zone Operation
- Code Guard/NAC Operation
- Mixed Mode Operation
- Scan Options
- Encryption Operation
- User Pick List Options
- Emergency Signaling
- Messaging Options
- Paging and Call Alert
- Other Functions & Options
- Backlight [LITE]
- Cloning
- Control Lockout [LOCK]
- Date and Time [DATE]
- Global Positioning [GPS]
- Hard Power Down [PWRD]
- Home [HOME]
- Inhibit/Uninhibit [INH]/UINH]
- Keypad Programming
- Minimum Volume [VOL]
- Monitor [MON]
- Nuisance Channel Delete [NUIS]
- Phone [PHN] and Hang Up [HANG]
- Radio Accountability Tone [RAT]
- Radio Info
- Repeater Talkaround [T/A]
- Send Alert Tone [SNDT]
- Send Signal [SEND]
- Squelch Adjust [SQL]
- Site Display [STDS]
- Site Lock [STLK]
- Site Search [STSR]
- Surveillance Mode [SURV]
- Transmit Digital [TXD]
- Transmit Power [PWR]
- Two-Tone Select [TONE]
- Versions
- Zone Select [ZONE]
- Keypad Programming Options
- 82 -
KNG Mobile Operation
Minimum Volume [VOL]
Conventional and Trunking Channels
Must be congured as "Customizable" in the PC Radio Editor to access through the
radio. When pressed, changes the volume level at lower volumes. This allows the user
to set their minimum volume to an audible level.
Monitor [MON]
Conventional Channels
There are three settings available for monitoring trac on a selected channel.
O - Requires NAC or Tone.
On - Monitors activity on selected frequency regardless of NAC or Tone.
Open - Open Squelch.
If assigned as a Touch Screen or function button, press the button to toggle On/O.
Press and hold for Open Squelch.
When assigned as a menu item, open the menu as described in the Navigation section
and select the Monitor mode you wish to use. Press "ENTER" to select.