User Manual
CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU
1955 Moss Court, Kelowna Date of Tests: October 16, 2001
B.C. Canada V1Y 9L3 FCC SAR Evaluation
_________________________________________________________________________________________________________
© 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A 4
Portable VHF PTT Radio Transceiver (150-174MHz)
Body-Worn SAR Measurements
Notes:
1. The SAR values found were below the maximum limit of 8.0 w/kg (controlled exposure).
2. The highest body-worn SAR value found was 0.965 w/kg (100% duty cycle).
3. The EUT was tested for body-worn SAR with the attached belt-clip providing a 1.4cm
separation distance between the back of the EUT and the outer surface of the planar phantom.
4. Ambient TEMPERATURE: 23.1 °C
Relative HUMIDITY: 57.3 %
Atmospheric PRESSURE: 100.2 kPa
5. Fluid Temperature ≈ 23 °C
6. During the entire test the conducted power was
maintained to within 5% of the initial conducted
power.
SAR
(w/kg)
Freq.
(MHz)
Channel Mode
Conducted
Power
(W)
Antenna
Position
Belt-Clip
Separation
Distance
(cm)
100%
Duty Cycle
50%
Duty Cycle
150.05 Low CW 5.3 Fixed 1.4 0.965 0.483
162.50 Mid CW 5.3 Fixed 1.4 0.645 0.323
173.95 High CW 5.3 Fixed 1.4 0.138 0.069
Mixture Type: Body
Dielectric Constant: 62.2
Conductivity: 0.80
ANSI / IEEE C95.1 1992 - SAFETY LIMIT
Spatial Peak Controlled Exposure/Occupational
BODY: 8.0 W/kg (averaged over 1 gram)
Body-worn SAR Test Setup
with 1.4cm Belt-Clip