User Manual

CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU
1955 Moss Court, Kelowna Date of Tests: October 16, 2001
B.C. Canada V1Y 9L3 FCC SAR Evaluation
_________________________________________________________________________________________________________
© 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A 3
Portable VHF PTT Radio Transceiver (150-174MHz)
4.0 SAR MEASUREMENT SUMMARY
The measurement results were obtained with the EUT tested in the conditions described in this
report. Detailed measurement data and plots showing the maximum SAR location of the EUT
are reported in Appendix A.
Face-Held SAR Measurements
Notes:
1. The SAR values found were below the maximum limit of 8.0 w/kg (controlled exposure).
2. The highest face-held SAR value found was 0.374 w/kg (100% duty cycle).
3. The EUT was tested for face-held SAR with a 2.5 cm separation distance between the front
of the EUT and the outer surface of the planar phantom.
4. Ambient TEMPERATURE: 23.1 °C
Relative HUMIDITY: 57.3 %
Atmospheric PRESSURE: 100.2 kPa
5. Fluid Temperature 23 °C
6. During the entire test the conducted power was
maintained to within 5% of the initial conducted
power.
SAR
(w/kg)
Freq.
(MHz)
Channel Mode
Conducted
Power
(W)
Antenna
Position
Separation
Distance
(cm)
100%
Duty Cycle
50%
Duty Cycle
150.05 Low CW 5.3 Fixed 2.5 0.374 0.187
162.50 Mid CW 5.3 Fixed 2.5 0.251 0.126
173.95 High CW 5.3 Fixed 2.5 0.138 0.069
Mixture Type: Brain
Dielectric Constant: 52.6
Conductivity: 0.76
ANSI / IEEE C95.1 1992 - SAFETY LIMIT
Spatial Peak Controlled Exposure/Occupational
BRAIN: 8.0 W/kg (averaged over 1 gram)
Face-held SAR Test Setup
2.5cm Separation Distance