Service Manual

19
RPU416A Adjust Description
2.CH: TX center,
turn to channel 1
0
in manual mode
Adjust it to:0.35kHz±50Hz Narrow
1.CH: TX center,
turn to channel 11
in manual mode
Adjust it to:0.75kHz±50Hz Wide
14.DQT DEV
2.CH:TX center,
turn to channel 1
2
in manual mode
Synthetical
test
LPF:300H
ANT
PTT
"
up
"
M
ONI
"
down
"
Adjust it to:0.35kHz±50Hz Narrow
15.Low
Battery level
Turn to channel
3
in manual mode,
A
djust the batter
y
to 5.8V
Digital
voltmeter
"
PTT
"
up
"
M
ONI
"
down
"
Adjust so that the LED flashes
"
Note:
In manual mode , channel selector 1-12, MIC can’t connect line, after adjust complete, short SELF, enter
mode setting press PTT, disable manual adjust.