Safety data sheet
Safety Data Sheet according to Regulation
(EC) No. 1907/2006 (REACH)
Religel - Hardener
Print date 12.02.2016
Revision date 12.02.2016
Version 1.0
4.3 Indication of any immediate medical attention and special treatment needed
No data available
SECTION 5: Firefighting measures
Additional information
Burning produces heavy smoke. Do not allow run-off from fire-fighting to enter drains or water courses. Use water
spray jet to protect personnel and to cool endangered containers. The product itself does not burn. Co-ordinate
fire-fighting measures to the fire surroundings.
5.1 Extinguishing media
No data available
5.2 Special hazards arising from the substance or mixture
No data available
5.3 Advice for firefighters
Special protective equipment for firefighters
In case of fire: Wear self-contained breathing apparatus.
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
No data available
6.2 Environmental precautions
Do not allow to enter into surface water or drains. In case of gas escape or of entry into waterways, soil or drains,
inform the responsible authorities. Ensure waste is collected and contained.
6.3 Methods and material for containment and cleaning up
For containment
Suitable material for taking up
Sand
Earth
Kieselguhr
Water (with cleaning agent)
For cleaning up
Unsuitable material for diluting or neutralising
Petroleum
6.4 Reference to other sections
Safe handling: see section 7
Personal protection equipment: see section 8
Disposal: see section 13
SECTION 7: Handling and storage
7.1 Precautions for safe handling
Advices on general occupational hygiene
When using do not eat, drink, smoke, sniff. Work in well-ventilated zones or use proper respiratory protection.
Draw up and observe skin protection programme. Use protective skin cream before handling the product.
Thorough skin-cleansing after handling the product.
Protective measures
Advices on safe handling
Never use pressure to empty container. Use only in well-ventilated areas.
Measures to prevent fire
No special fire protection measures are necessary.