Specifications

IP Office Product Description
IP Office 4.2
© 2008 AVAYA All rights reserved.
Page 292
Issue 18.b.- (08 July 2008)
Telephone Extension Cable Lengths
The following table details the maximum cable lengths supported for the telephone ranges. These figures
assume that standard twisted-pair telephone cable or CAT5 network cable is used.
Telephone
Unshielded Twisted-Pair (UTP) - 50nf/Km
CW1308
AWG22
(0.65mm)
AWG24
(0.5mm)
AWG26
(0.4mm)
2400/5400 Series
1200m/3937'.
1000m/3280'.
670m/2200'.
400m/1310'.
4406D Phone
1000m/3280'.
1000m/3280'.
400m/1310'.
400m/1310'.
4412D Phone
1000m/3280'.
700m/2295'.
400m/1310'.
400m/1310'.
4424D
500m/1640'.
500m/1640'.
400m/1310'.
400m/1310'.
6400 Series
1000m/3280'.
1000m/3280'.
400m/1310'.
400m/1310'.
T3 Series (Upn)
1000m/3280'.
1000m/3280'.
400m/1310'.
Analog Phones
1000m/3280'.
1000m/ 3280'.
400m/1640'.
800m/2620'.
Heat Dissipation
Note that the above numbers are for reference only. For practical purposes, for example the calculation of heat
dissipation, it is recommended to base environmental requirements (for example air cooling or UPS ratings) on
the maximum input rating of the power supplies of the planned IP Office configuration, as follows.
In order to calculate the maximum, that is worst case, amount of heat that can be generated by an IP Office
system, it is assumed that all input power is converted to heat; whether from the PSU itself, the system unit,
expansion module and/or cabling.
Heat dissipation is normally measured in British Thermal Units (BTU's). A heat value expressed in Watts can be
converted to BTU/hr by multiplying by 3.41297. As indicated above, you should use the maximum power input
of 115 VA of each power supply to calculate this most accurately.
Using the conversion factor:
· Heat Dissipation = 115 x 3.41297 = 392.5 BTU/hour.
The metric equivalent to BTU is a Joule where 1 BTU = 1,055 Joules.
This calculates the BTU value per power supply. The maximum BTU per system is therefore calculated, based
on total number of power supplies installed in the system. For example, for a IP412, this would be 1 for the
base unit and up to 12 for the expansion modules.
· IP412 Maximum Heat Dissipation = 13 x 392.5 = 5,103 BTU/hr.
Remember to budget for the power requirements of any additional devices that are to be co-located with the
IP Office such as server PC's (voicemail, etc).
Power Supply
· Input
· Small Office Edition: 2.5mm DC inlet socket. 24Vdc power input. Rating 24V DC, 1.8A maximum.
· IP406 V2, IP412 and expansion modules: 2.5mm DC inlet socket. 24Vdc power input. Rating
24V DC, 2A maximum.
· IP Office 500 System Unit: IEC AC inlet socket. 100-240V AC, 50/60Hz, 81-115VA, 2.5A
maximum.
· Power Supply Units: All CE/UL/Dentori Safety Approved.
· Standard 40W Power Supply Unit (All control and expansion units unless otherwise indicated)
Supplied with the control or expansion unit. 40W PSU with integral lead to the unit. Connection to
switched mains supply requires separately supplied country specific IEC 60320 C7 power cord
(2-wire figure 8 connector).
· Input: 100-240V AC, 50/60Hz, 81-115VA, 2A maximum.
· Output: 24Vdc, 1.875A, output power 45W maximum.