ATTACHMENT COUPLINGS
If the attachment connections dry up after intensive use, put a small amount of
lubricant(Vaseline)aroundtheO-ringsonthemaleattachment.
TECHNICAL DESCRIPTION
120VPower 1750W
Coldwatertankcapacity 2L
Workingpressure 4bar
Safety valve Yes
REPLACEMENT & OPTIONS
#3KSPGS010 Nylonbrush
#3KSPGS015 Brassbrush
#3KSPGS025 Stainlesssteelbrush(notsuppliedwithsteamcleaner)
#7TPAC0200 Replacementcloths(2/pack)
#7ZSODC030 Cleaningpowder
TROUBLESHOOTING
Donotoperatethesteamcleanerwithadamagedcord,plugorifthesteam
cleanerhasbeendroppedordamaged.Toavoidriskofelectricshock,donot
disassemble or attempt to repair the unit on your own. Return the unit to Reliable
Corporation(seewarranty)forexamination,repairorreplacement.
PROBLEM
No steam is released through
the steam fittings.
Dropsofwaterleakfromthe
attachments.
Dirtywateriscomingout.
Not enough steam pressure.
REMEDY
1. Turn steam unit onto the
2nd position.
2. Put required amount of
waterintotank.
3. Plug unit into outlet.
4. Waitforlight(3)toturnon.
1. Waitforlight(3)toturnon.
2. Letwaterrunthroughsys-
tem until steam comes out.
1. Followcleaninginstructions
inbook.
1. Turn the dial until the de-
sired pressure is reached.
POSSIBLE CAUSES
1. Steam unit is not turned on.
2. Watertankisempty.
3. Unitisnotpluggedin.
4. Generatorisnotfully
heated.
1. Unitisnotfullyheated.
2. Condensation was created
from non-use.
1. Scale may have built up.
1. The dial on the handle may
be set too low.