Instruction manual
TROUBLESHOOTING
Donotoperatethesteamcleanerwithadamagedelectricalcord,plugorifthe
steamcleanerhasbeendroppedordamaged.Toavoidriskofelectricshock,donot
disassembleorattempttorepairtheunitonyourown.ReturntheunittoReliable
Corporation(seewarranty)forexamination,repairorreplacement.
EP1000 TROLLEY ASSEMBLY INSTRUCTIONS
1. Trolleybaseunit
2. Traytocarryaccessories
3. Trolleyhandle
4. Rotatingwheels(2)
5. Backwheels(2)
6. Chromebackwheelcover(4)
7. Selflockingnuts(2)
8. Washers(4)
9. Brasswheelcover(2)
10. Fixingcap(4)
11. Waterbottlewithtap
12. Transparentsiliconehose
13. Cap
14. Wrench
10
(PROBLEM)Thereisnosteam,allthelightsremainonandthepumpiscontinuouslyrunning.
(POSSIBLECAUSES)1.You'reusingtoomuchsteam(pos.4).2.Waterpumpisbroken.
(REMEDY)1.Turnoffmainswitch(1)wait1minutethenturnbackandwaitforgreenlight(A)
toturnon.2)ContactReliableCorporationforservice.
PROBLEM
Nosteamisreleasedthrough
thesteamttings.
Waterdropsleakfromthe
attachments.
Dirtywateriscomingout.
Notenoughsteampressure.
REMEDY
1. Turnonmainswitch(1)
2. Iftheredlight(B)isashing
onandoffandyoucanhear
anoise,llupthetank.
3. Plugunitintooutlet
4. Waitforthegreenlight(A)
toturnon.
1. Waitforlight(A)toturnon.
2. Letwaterrunthroughsys-
temuntilsteamcomesout.
1. Followcleaninginstructions
inbook.
1. Turnthedialuntilthede-
siredpressureisreached.
POSSIBLECAUSES
1. Steamunitisnotturnedon.
2. Watertankisempty.
3. Unitisnotpluggedin.
4. Generatorisnotfully
heated.
1. Unitisnotfullyheated.
2. Condensationwascreated
fromnon-use.
1. Scalemayhavebuiltup.
1. Thedialonthehandlemay
besettoolow.