1 - Description
R2BC Storage water heater (further “tank“) with two enameled heating coils with G 5/4” connections (e.g. for
connecting a solar system and a heat pump), enabling installation of an electric heating element and also an-
other el. heating element or a nned tube heat exchanger into the ange of the lateral inspection hole.
In order to reach proper working of the tank, it is necessary to design optimum hydraulics of the whole system,
i.e. position of circulation pumps for sources and heating circuits, valves, non-return valves etc.
1.1 - Models
Ten models of 200, 300, 400, 500, 750, 1000, 1500, 2000, 2500 and 3000l capacity enabling installation of an
electric heating rod or another heat source.
1.2 - Tank protection
Enameled inner surface and coil guarantee long service life. Enamel is done according to DIN 4753 standard.
Further qualitative improvement is reached thanks to a magnesium anode installed inside the tank. From the
volume of 400l upwards each tank has 2 anode rods. The 3000l tank has 3 anodes.
1.3 - Thermal insulation
Tanks of volume up to 500l are supplied with a hard polyurethane insulation 50mm thick with a white PVC
surface. Tanks of 750 and 1000l volume are supplied with a hard polyurethane insulation 75mm thick with
a white leatherette surface. Tanks of 1500, 2000, 2500 and 3000l volume have the insulation 100mm thick.
The insulation can be detached for easier handling.
1.4 - Connection points on the tank
4× lateral with G 5/4“ inner thread, to the heating coils
2× lateral with G 5/4“ inner thread, for cold water inlet and hot water outlet
3× lateral with G 1/2“ inner thread, for temperature probes and a thermometer
1× lateral with G 1“ inner thread, for recirculation
1× top with G 5/4“ inner thread, for a magnesium anode rod
1× lateral with G 6/4“ inner thread, for an el. heating rod
ange for the lateral inspection hole
1.5 - Packing
Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap. It is forbidden to transport
and/or store the storage tanks in a horizontal position.
2 - General Information
This Owners Manual is an integral and important part of the product and must be handed over to the User.
Read carefully the instructions in this Manual as they contain important information concerning safety, installa-
tion, operation and maintenance. Keep this Manual for later reference.
Using the tank for other purposes than stated above is forbidden and the manufacturer accepts no responsibil-
ity for damage caused by improper or wrong use.